current transformer 100A
current transformer 100A
Current Transformers(CT's)
current transformer 200A
Current Transformers(CT's)
current transformer 400A
Current Transformers(CT's)
Current Transformers(CT's)
Current Transformers(CT's)
Current Transformers(CT's)
CURRENT TRANSFORMER 600A
Current Transformers(CT's)
Current Transformers(CT's)
Current Transformers(CT's)
Current Transformers(CT's)
current transformer 200.5A
current transformer 400.5A
Current Transformers(CT's)
Current Transformers(CT's)
Current Transformers(CT's)
Current Transformers(CT's)

Current Transformers(CT's)

SKU: ICI30CT108-B

Current Transformers(CT's)

SKU: ICI30CT108-B
Amps
Core Type
Regular price $34.99 CAD
/
  • International Ship
  • Secure payments
  • In stock, ready to ship
  • Backordered, shipping soon
Shipping calculated at checkout.

To determine the amount of Amperage Points/CTs needed in your assembly for ever meter point, it will vary on the voltage system.

  • 120V_1ø2 wire voltage systems require 1 CT per meter point (1:1).
  • 120/240V_1ø3 wire and 120/208V_2ø3 wire voltage systems require 2 CTs per meter point (1:2).
  • 120/208V_3ø4 wire, 240/416V_3ø4 wire, 277/480V_3ø4 wire, 347/600V_3ø4 wire, 208V_3ø3 wire, 416V_3ø3 wire, 480V_3ø3wire and 600V_3ø3 wire voltage systems require 3 CTs per meter point (1:3).

Solid Core


The window size varies on the amperage
Ratio Inside Diameter Inches Outside Diameter Inches Thickness Inches Weight gr/lbs Lead Length in ft. MC Approval UL FIle
100:0.08 0.5 1.1 x 1.2 0.78 69 / 0.15 6 AE-2486 UL2808, File No. E515601
200:0.1 0.76 1.8 0.7 100 / 0.22 6 AE-248 UL2808, File No. E515601
200:0.08 0.76 1.8 0.7 100 / 0.2 6 AE-2585 UL2808, File No. E515601
400:0.1 1.69 3.07 1 254 / 0.5 6 AE-2566 UL2808, File No. E515601
400:0.08 1.69 3.07 1 254 / 0.56 6 AE-2566 UL2808, File No. E515601
600:0.1 3.54 5.7 1 655 / 1.44 6 AE2566 UL2808, File No. E515601
600:0.08 3.54 5.7 1 655 / 1.44 6 N/A UL2808, File No. E515601
800:0.1 5.9 8.66 1.57 1,587 / 3.5 6 AE-2566 UL2808, File No. E515601
800:0.08 5.9 8.66 1.57 1,587 / 3.5 6 N/A UL2808, File No. E515601
1000:0.1 5.9 8.66 1.57 1,587 / 3.5 6 N/A UL2808, File No. E515601
1000:0.08 5.9 8.66 1.57 1,587 / 3.5 6 N/A UL2808, File No. E515601
200:5 3/4 2 0.6 2 AE-1368 rev.1 C/US UL recognized
400:5 1 1/2 3 1/2 0.9 2 AE-1180 CSA & UL recognized
600:5 3 1/4 2.78 5.6 X 5.6 NO Leads T-188 CSA & UL recognized

Split Core


The window size varies on the amperage:
Window Lead Length
100:0.033A - 0.75" 2ft.
Note: To be used with a Multiplier of 3 or special programming of the i-meter45
100:0.1A - 0.75" 2ft.
200:0.1A - 0.75" 2ft.
Note: Recommended for use with the MF-Series Meter and i-meter-636
400:0.1A - 1.25" 2ft.

This site is protected by hCaptcha and the hCaptcha Privacy Policy and Terms of Service apply.