EVCMC-1B-40A

EVCMC-1B-40A, is an EV Energy Management System specifically designed to allow the connection of a charger to the main feeder of the panel without affecting the load capacity limit of the feeder.


Ideal for the installation of chargers in single-residential units. Thanks to its NEMA 3R outdoor enclosure it is also suitable for outdoor installations.


How it works:

  • EVCMC-1B-40A allows the connection of any EV charger to a fully loaded panel by managing the energy available at any given time
  • It detects when the total power consumption of the main circuit breaker exceeds 80% and at that point temporarily de-energizes the charger
  • 3. When the EVCMC detects that the total power consumption of the electrical panel, including the load of the EV Charger, is less than 80% for more than 15 minutes it automatically re-energizes the charger
  • Can be ceiling or wall mounted
evcmc-1B-40A


The EVCMC will only allow power to be delivered to the EV charger if the total demand of the panel is below its full capacity. The new EVCMC-1B-40A has the ability to receive and transmit load shedding instructions from an external energy management system via a dry contact input and output.


Features:

  • Ideal when no more breaker slots are available in a panel
  • Does not affect the limit set by the load calculation of the main distribution panel
  • It is installed downstream from the Utility Meter, accounting for the EV Charger consumption in the bill